Keeler KAT Contact Applanation Tonometer
Quick Overview
Based on the industry bench mark of the 'Goldmann Standard' of intraocular pressure (IOP) measurement, the Keeler KAT Contact Applanation Tonometer is a perfect example of skill and engineering that has been applied to a 21st Century design from a 20th Century device to deliver a premium quality instrument.
The Keeler KAT is made with precision-machined components that are subject to stringent quality controls at Keeler’s Windsor factory ensuring a design that is manufactured to the exacting standards you would expect from a Keeler instrument.
Available in both R-Type & T-Type variants. The R type can be fixed to the slit lamp. The T type is removable and is convenient to use on multiple slit lamps.
Features
- Goldmann applanation principle: The Goldmann applanation principle is widely acclaimed as the most common and direct method of assessing IOP.The KAT is made with precision machined components, subject to stringent quality controls pre, during and after assembly to add reliability and repeatability to an established technique.
- T type, R type: The take-away T type KAT is fitted to the guide plate on the optical axis for the microscope and illumination unit arm. The fixed R type is mounted on a post fitted to the microscope optical body.
- Robust and reliable: Our all metal parts, manufactured to a high precision engineering design will withstand the test of time and deliver reliable results year after year.
Part Number
Keeler KAT Applanation Tonometer T Type
Part #: 2414-P-2030
Keeler KAT Applanation Tonometer R Type
Part #: 2414-P-2040
Specifications
Measurement force: By leverage weight
Installation: Fitted to the guide plate
Keeler T type: for towerillumination Slit Lamps:Fitted to the guide plate on the optical axis for the microscope and illumination unit arm.
Keeler R type: for tower illumination Slit Lamps: Mountable on a post fitted to the microscope optical body.
Measurement range: 0 - 80 mmHg, (0 – 10.64 kPa)
Approximation of the impact force on the measurement head for a 0 to 58,84 mN measurement range: Standard divergence: 0.49 mN <_ 3s <_ 1.5% of nominal value
Operating temperature range: from 10°C to 35°C
Measurement accuracy: <_ 0.49 mN
Net weights:
Keeler T type: 0.41 kg (without accessories)
Keeler R type: 0.69 kg (without accessories)
KAT Aluminium carrying and storage case Part #: 3414-P-7000 |
|
KAT doubling prism Part #: 2414-P-5001 |
|
KAT T type guide plate Part #: 2414-P-5032 |
|
KAT R type post Part #: 2414-P-5042 |
|
Calibration arm assembly Part #: 2414-P-5005 |