Keeler D-KAT Digital Contact Applanation Tonometer
Quick Overview
The latest addition to the Keeler product portfolio is the D-KAT Digital Contact Applanation Tonometer. Based on the industry bench mark of the 'Goldmann Standard' of intraocular pressure (IOP) measurement.
Designed and manufactured in the UK to the exacting standards you would expect from a Keeler instrument. The Keeler D-KAT Digital Contact Applanation Tonometer delivers reliability and ease of use.
It operates according to the 'Goldmann Standard', by measuring intraocular pressure from the force required to flatten (applanate) a constant area (3.06mm) of the cornea.
This product provides a fast and accurate measure of IOP, with an LED display and internal electronics.
Available in both T-Type and R-Type forms. The T type is easily removable and allows for convenient usage on multiple slit lamps, while the R type can be directly fixed to a slit lamp.
Features
- The LED display and internal electronics allows for fast and accurate measurement of intraocular pressure (IOP). With fewer moveable parts, the D-KAT is far more reliable and accurate and recalibration takes only a few seconds.
Part Number
Keeler D-KAT Digital Applanation Tonometer T Type
Part #: 2414-P-2032
Keeler D-KAT Digital Applanation Tonometer R Type
Part #: 2414-P-2042
Specifications
Keeler digital T type: for Haag Streit type illumination systems: Fitted to the guide plate on the optical axis for the microscope and illumination unit arm
Keeler digital R type: for some Zeiss type and Haag Streit type illumination systems Mountable on post on microscope
Installation: Assembled on the guide plate on the slit lamp arm or mounting post
Measurement range: 5–65 mmHg (0.66 – 8.46kPa)
Measurement deviation: 0.49 mN or 1.5% of measurement value, whichever is the greater
Operating temperature: range From 10ºC to 35ºC
Reverse span (Hysteresis): " 0.49 mN
Net Weight:
- Keeler T type: 0.37 kg (without accessories)
- Keeler R type: 0.58 kg (without accessories)
Environmental - Ambient Conditions
Transportation
- Temperature: -40ºC to +70ºC
- Air Pressure: 500 hPa to 1060 hPa
- Relative humidity: 10% to 95%
Storage
- Temperature: -10ºC to +55ºC
- Air Pressure: 700 hPa to 1060 hPa
- Relative humidity: 10% to 95%
Use
- Temperature: +10ºC to +35ºC
- Air Pressure: 800 hPa to 1060 hPa
- Relative humidity: 30% to 75%
KAT Aluminium carrying and storage case Part #: 3414-P-7010 |
|
KAT doubling prism Part #: 2414-P-5001 |
|
KAT T type guide plate Part #: 2414-P-5032 |
|
KAT R type post Part #: 2414-P-5042 |
|
Calibration arm assembly Part #: 2414-P-5005 |
|
Battery Part #: 1909-P-7129 |